Diamond Anti-Reflection Coating
Diamond is an important material choice for sampling optical elements in Fourier transform-infrared (FT-IR) spectroscopy.
Diamond is an important material choice for sampling optical elements in Fourier transform-infrared (FT-IR) spectroscopy. The multi-phonon absorption in the mid-infrared, although temperature dependent, is weak for thin optical elements and can be referenced to an empty cell background. However, the cost of diamond optics requires the sampling area to be very small. As a result, the signal-to-noise ratio (SNR) advantages of the FT-IR systems are frequently stretched to the limit and more energy throughput is usually quite helpful.
Frequently the sampling technique of choice is attenuated total reflection (ATR) for its benefits of ease of analysis. ATR elements can be manufactured from most optical materials of relatively high refractive index. Ge, Si, ZnSe, ZnS, KRS-5, and diamond is often used for this application. For most of these materials, a broad band anti-reflection (BBAR) coating can be applied to both surfaces of a window or the entrance and exit facets of an ATR element and can significantly increase the energy throughput of the sampling accessory or system.
Since diamond and ZnSe have similar refractive indexes a similar BBAR can be used on Diamond once the binding layers of the coating are appropriately modified.
Spectral Systems has developed its Diamond XP-BBAR(tm) coating with spectral performance as shown in Figure 1.
Figure 1: Transmission spectrum of uncoated Diamond window shown in blue. Transmission spectrum of Diamond XP-BBAR coating on both sides of a Diamond window shown in green.
It is seen in Figure 1 that the energy and thus the SNR is about 30% better through most of the analysis region of a typical FT-IR instrument.
Since there are no suitable coating materials for the very long wavelength portion of the spectrum the coated element is not as good, but still usable, below 600 cm-1. If a liquid nitrogen cooled MCT detector is used, this portion of the spectrum is usually not recorded by the spectrometer.
Spectral Systems
35 Corporate Park Drive, Hopewell Junction, NY 12533
tel. (845) 896-2200, fax (845) 896-2203
Website:
Articles in this issue
about 11 years ago
Miniature 60 kV, 1000 μA 12 W X-ray Sourceabout 11 years ago
Cost Savings Comparison: CVAA Versus Direct Mercury Analysisabout 11 years ago
Applications in Gemology Using the TSI LIBS Desktop Analyzerabout 11 years ago
Two Excitation Wavelengths Are Better than Oneabout 11 years ago
Spectroscopy’s New Role in Document Securityabout 11 years ago
Analysis of Agricultural Soils and Plant Materialsabout 11 years ago
Optimized Grazing Angle Ge-ATR of Monolayers and Thin Films on Siabout 11 years ago
Infrared Transmission Measurements of Diffuse SamplesRelated to this article