Register Now: Advances in Spectroscopy for Pharma and Biopharmaceutical Analysis Symposium
|Webcasts|September 15, 2021

Interferences Explained, ICP-OES Part 1

Wednesday, September 15, 2021 at 11am EDT| 8am PDT| 4pm BST| 5pm CEST Do you have problems with false positive or negative results with your ICP-OES or ICP-MS analyses? Are you wondering where the interferences causing these errors are coming from? If so, join this webinar to learn how to identify interferences, develop strategies to manage them and discover new hardware solutions that enable unprecedented levels of accuracy for your elemental analysis.

Register Here: http://www.spectroscopyonline.com/spec_w/ICPOES

Event Overview:

Interferences are a well-known problem in both inductively coupled plasma–optical emission spectroscopy (ICP-OES) and ICP–mass spectrometry (ICP-MS). They can be subdivided into three main types: chemical, physical, and spectral.

  • Chemical interferences are caused by differences in the way sample and calibration solution matrices behave in the plasma, resulting in changes in atomization and ionization that are dependent on the matrix composition of the sample. An example of this type of interference is the enhancement effect (which causes falsely high results) observed on both atom and ion signals for elements such as arsenic and selenium, when carbon is present in the samples but not the calibration solutions.
  • Physical interferences are also caused by matrix differences between samples and calibration solutions. Examples of this type of interference include signal suppression (due to high amounts of easily ionized elements, such as sodium, in the samples), drift and signal variability from sample to sample caused by, for example, changes in nebulization efficiency as a result of viscosity differences between samples. These interferences can cause reported results to be either too high or too low if they are not properly corrected for.
  • The last, and most challenging, type of interference is spectral interference. For ICP-OES, these are observed as either direct or partial emission wavelength overlaps on the signals of target analytes from other elements or molecular species in the sample. For ICP-MS, spectral interferences from other elements in the sample appear as either direct (from singly charged ions) or half-mass (from doubly charged ions) overlaps on the target ion isotope signals. With ICP-OES, spectral interferences, like physical interferences, can cause falsely high or falsely low results. With ICP-MS, the overlaps caused by interfering signals generate false positive signals, but if incorrect mathematical corrections are applied to the data, falsely low results can also be reported.

In this two-part webinar series, the sources of interferences in ICP-OES and ICP-MS and how to identify them will be described. Software approaches for correcting interfered results which each technique will be presented and the latest instrumental developments for minimizing interference problems will also be discussed.

Key Learning Objectives:

  • Understand what types of interferences exist in ICP-OES and ICP-MS and how they affect your results.
  • Learn strategies for identifying and managing these interferences.
  • Find out how innovations in hardware help reduce interferences, improve accuracy, and remove the need to re-run samples.
  • Discover how intelligent software tools enable easier, interference-free method development.

Who Should Attend:

  • Analysts wishing to enhance their elemental analysis knowledge
  • Instrument operators who encounter problems with inaccurate data and want to know how improve their results.
  • Laboratory managers who need to lower detection limits, reduce sample re-runs, and accelerate sample turnaround times


Register Here: http://www.spectroscopyonline.com/spec_w/ICPOES

Related to this article

Mapping Molecular Mobility Pixel by Pixel
Garth Simpson of Purdue University explains how patterned photobleaching and spatial Fourier transforms can turn a single-point measurement into a diffusion coefficient at every pixel in the field of view.
Optical and Electronic Instrument Components,  ©  ridwan -chronicles-stock.adobe.com
The updated and expanded 2026 edition of Spectroscopy's Instrument Components Terminology Guide defines the sources, detectors, optical and dispersive elements, sampling hardware, physical constants, and unit conversions used across UV-vis, NIR, IR, Raman, X-ray, and atomic spectroscopic instrumentation, with new terms reflecting component developments reported between 2022 and 2026.