Finding Gold Just Became Easier than Ever Imagined
Photonic Knowledge, Inc., a spin-off of Photon etc., introduces the Core Mapper?, a hyperspectral imager that produces instantaneous, precise in situ mineralogy, lithology, and alteration mapping. This unique patented technology answers the increasing demand of the mining industry for better exploration tools.
Sébastien Blais-Ouellette1 and Christian Sasseville2, 1Photon etc. and 2Photonic Knowledge, Inc.
Photonic Knowledge, Inc., a spin-off of Photon etc., introduces the Core Mapper™ , a hyperspectral imager that produces instantaneous, precise in situ mineralogy, lithology, and alteration mapping. This unique patented technology answers the increasing demand of the mining industry for better exploration tools.
Based on Photon etc's hyperspectral imaging technology the Core Mapper™ delivers a series of monochromatic images at user-specified wavelengths between 400 and 1000 nm, offering instant in situ mineral identification. The hyperspectral imager simultaneously analyses five drill core boxes with a spatial resolution of 1 mm2 per pixel and a field of view of 1.5 m2 . Spatial resolution is 900 times better and field of view is 1666 times wider than any currently available hand-held mineral spectrometer. It can provide fast mineralogy fields mapping services, as high as 1500 drill core meters per day with one imager.
Experimental Conditions
Using the optimized Hyperspectral Imager designed specifically for mineral identification, Photonic Knowledge demonstrated the unique precision of the Core Mapper™ to a mine site in the Rouyn-Noranda region (Figure 1).
Figure 1: Transportable laboratory setup.
Two drilling holes were dug and assessed. Gold analysis performed on the core of the first hole indicated gold values averaging 5 to 7 g/ton. The second hole was only partially sampled based on the geologist's assessment and labelled "of limited interest." No supplementary gold assays were performed on the second hole.
Optical spectra provide crystal field characteristics of transition metals, lathanides, actinides, and spectro-chemical clues on ligand contents. Using the Core Mapper™, Photonic Knowledge identified proper weighting of spectral classes vectorizing the gold mineralization on the first hole. This algorithm was then applied to the second hole and the same gold vectors were identified. Assays were subsequently performed on samples from the second hole yielding 0.1 g/ton to 0.5 g/ton, averaging 0.2 g/ton on 5 meters illustrating the accuracy and detection limit of the Core Mapper™ as well as the high potential for ore vectorization (Figure 2). Although subeconomic, this finding was significant as an indicator of proximity to the main mineralization zone.
Figure 2: Example of ore vectorization.
Conclusion
Resulting in more than just an increase in efficiency, the Hyperspectral Imager supplies information on both spectral and spatial content, creating new opportunities for analysis, pushing the boundaries of the most demanding applications in mineral identification. Photonic Knowledge's optimized hyperspectral cube allows for spectral analysis of each and every pixel of a full resolution image, amounting to no more fastidious x-y scanning of the samples.
The Core Mapper™ technology affords the mining industry the opportunity to see things never seen before. The precision and speed with which it performs diagnostics of material, physical, or molecular is unparalleled. With a single acquisition, the photonic imaging system discovers gold bearing zones in a way geologists have only dreamed about!
Photon etc.
5795, Gaspé, #222, Montreal, Quebec, H2S 2X3, Canada
tel. (514) 385-9555, fax (514) 279-5493
Website:
Photonic Knowledge
481 Grande-Côte, Rosemère, Quebec, J7A 1M1, Canada
tel. (450) 965-9913, fax (450) 621-8706
Website:
Articles in this issue
over 14 years ago
Generating Purge Gas for FT-IR Spectroscopyover 14 years ago
Fat Analysis in Food and Feed with NIRover 14 years ago
QA/QC of Coatings and Surfaces via Exoscan Handheld FT-IR Analyzerover 14 years ago
Mapping Protein Conformational Stability Using Automated CDover 14 years ago
The Application Notebook - A Stable Force Over the YearsNewsletter
Get essential updates on the latest spectroscopy technologies, regulatory standards, and best practices—subscribe today to Spectroscopy.