ABB to Develop Mars-Tuned OA-ICOS Spectrometer for Methane Detection
Key Takeaways
- Primary objective is ultra-sensitive near-surface methane quantification on Mars, with instrument design intended to later support O₂, HCl, and H₂O measurements.
- Engineering work targets noise reduction and sensitivity gains to reach ppb detection despite low surface pressure and limited absorbing molecules along the optical path.
The Canadian Space Agency contract funds refinement and prototype testing of a laser-based cavity spectrometer intended to monitor trace methane continuously at the Martian surface.
On November 17, 2026, ABB announced that the Canadian Space Agency (CSA) awarded them a contract to further develop a compact gas spectrometer designed to detect and quantify near-surface trace gases, including methane, on Mars. The work falls under the Martian Atmospheric Gas Evolution Experiment (MAGE), part of the CSA’s Space Technology Development Program.1
The instrument is a Mars-tuned version of ABB’s off-axis integrated cavity output spectroscopy (OA-ICOS) technology, which is a laser absorption technique the company currently markets for detecting and tracking methane leaks on Earth.1 Under the contract, ABB engineers and scientists will refine the design, build a functional prototype, and test it under conditions representative of the Martian surface and its atmospheric gas mixture.1
What is the main objective of the compact gas spectrometer?
According to ABB, the primary objective is highly sensitive methane detection. At the same time, the instrument’s architecture is being developed so it can later measure oxygen, hydrogen chloride, and water vapor.1 Much of the development effort will focus on reducing measurement noise and maximizing sensitivity.1
Quantifying near-surface trace gases like methane will be one of the challenges in constructing this compact gas spectrometer. Because methane is present in the Martian atmosphere at approximately 1 part per billion (ppb), and surface atmospheric pressure is far lower than on Earth, this reduces the number of absorbing molecules available along any optical path.1 As a result, the analytical requirements are incredibly demanding.
Another challenge that will be addressed with the development of this gas spectrometer is the MAGE mandate. Because it calls for hourly measurements so that temporal fluctuations in methane concentration can be tracked and used to help narrow down its source, it further makes the analytical requirements needed that much tougher.1
What is the importance of surface monitoring?
Surface monitoring is important because it helps researchers know which gases exist on other planetary bodies. Using Mars as an example, traces of methane have been detected using surface monitoring, but the problem is that these traces are unresolved.1 Because methane breaks down over time when exposed to sunlight, its continued presence suggests that an active source may be replenishing it.1
ABB noted in their press release that previous investigations have been limited to remote observations from orbit or to highly localized measurements at individual sampling sites.1 According to the company, continuous, high-sensitivity monitoring of atmospheric trace gases at the surface would effectively expand the searchable area and could reveal methane activity that existing techniques have not been able to detect.1
“What makes this technology exciting is that it allows us to search for trace gases in a completely different way,” said Frederic Pelletier, Business Development Manager for Space & Defense at ABB’s Measurement & Analytics division, Canada, in a press release.1 “Rather than examining a small sample collected from a single location, we can monitor gases originating from a much larger area. If successful, this capability could help us identify the processes responsible for methane’s presence on Mars, one possibility being that methane is generated by microbes buried underground in the same way shale gas is trapped on Earth.”
How does OA-ICOS work?
OA-ICOS directs an infrared (IR) laser into a sample cell bounded by highly reflective mirrors.1 Aligning the beam off the cavity axis causes the light to make many passes through the gas, producing a long effective path length in a compact cell and allowing very low concentrations to be measured.1 For its leak-detection products on Earth, ABB reported sensitivity more than 1000 times higher than conventional technologies.1 The company also says these products detect methane and ethane at single-ppb levels 10 times faster than traditional equipment.1
Getting that performance on Mars means keeping detection limits low at reduced pressure, in an atmosphere very different from Earth’s.1 That is what the prototype testing in the contract is meant to address.
Reference
- ABB, ABB to Advance Methane Detection Technology for Future Mars Missions. ABB, 2026.
https://new.abb.com/news/detail/140269/abb-to-advance-methane-detection-technology-for-future-mars-missions (accessed November 18, 2026).