Spectroscopy Top 10 Articles of the Month (October 2026)
The following articles are the most accessed digital object identifier (DOI) manuscripts for Spectroscopy and LCGC International during the month of October 2026. Nine articles are individually ranked here by DOI page views; the seventh-highest entry (99 views) was recorded against the bare LCGC North America journal-level DOI rather than an individual article and is therefore not attributable to a single manuscript.
Each article has been selected based on the number of successful DOI page views by readers as reported by reports@crossref.org. The articles showcase key developments and insights in spectroscopy and chromatography. Spectroscopy covers the main topics of electronic spectroscopy, vibrational spectroscopy, magnetic resonance, imaging techniques, atomic spectroscopy, and data analysis and integration. LCGC covers most aspects of liquid and gas chromatography, mass spectrometry, and related technical aspects of separation science.
This month's ranking is led by Sergei Leikin and Autumn Phillips's evaluation of ICP-OES as a practical alternative to ICP-MS for trace elemental analysis, which drew 1,063 DOI views—nearly seven times the next-ranked article. Brian C. Smith's Infrared Spectroscopy of Polymers series again dominates the list with five of the nine individually ranked spots, joined by continued reader interest in the Raman spectroscopy of proteins, a practical treatment of partition coefficients in extraction science, and online ATR-FT-IR monitoring of a pharmaceutical esterification reaction from Spectroscopy and LCGC.
1.
Authors: Sergei Leikin and Autumn Phillips
Inductively coupled plasma–mass spectrometry (ICP-MS) is the most widely used technique for ultratrace elemental analysis because of its extremely high sensitivity, but inductively coupled plasma–optical emission spectroscopy (ICP-OES) is simpler to operate, tolerates higher matrix loads, and is less costly to maintain. This column examines whether ICP-OES, when fitted with a high-efficiency nebulizer, can serve as a practical alternative to ICP-MS for certain applications. The authors enhanced ICP-OES sensitivity using a robust sample introduction system in which an external impact surface is positioned close to the nebulizer gas orifice at an optimized angle, while a non-concentric design keeps the gas and sample channels separate throughout the nebulizer body. Applying this approach to a select group of sample matrices, they demonstrate that ICP-OES can meet challenging detection limits that might otherwise require ICP-MS.
2.
Author: Brian C. Smith
Polyethylene remains one of the most important commercial polymers and serves as an excellent model system for learning polymer infrared spectroscopy. This article continues the discussion of polyethylene spectral interpretation, showing how synthesis methods affect polymer morphology and spectroscopic behavior. Particular attention is given to crystalline splitting and methylene rocking vibrations, illustrating how subtle spectral changes reveal structural differences in polyethylene materials.
3.
Author: Brian C. Smith
This article examines the infrared spectroscopy of polyurethanes, comparing their spectral behavior to the structurally related polyamides. Polyurethanes contain secondary urethane linkages that combine ester- and amide-like character around a shared carbonyl group, and the discussion reviews the resulting N–H stretching, carbonyl, and C–O vibrations. A key diagnostic point is that urethane C=O stretches appear at higher wavenumbers than those of amides, helping distinguish the two polymer classes. The article also covers the diisocyanate precursors used in polyurethane synthesis, which display an intense, broad N=C=O asymmetric stretch near 2277 cm⁻¹.
4.
Author: Brian C. Smith
This is the third installment in Smith's ongoing series on polymer infrared spectroscopy, building on the earlier discussion of polyethylene to examine two additional hydrocarbon polymers: polypropylene and polystyrene. The article provides detailed analysis of how these materials' infrared spectra differ from one another and from polyethylene, demonstrating how characteristic absorption bands distinguish among hydrocarbon polymer types. The discussion serves as both a practical materials-identification resource and an educational review of infrared spectral interpretation technique.
5.
Author: Fran Adar
In this installment of her Raman column, Adar reviews the band assignments of protein Raman spectra and explains why knowing those assignments helps researchers use Raman data to probe protein structure and function. Using the spectrum of a fingernail (α-keratin) as a representative example, the article works region by region through the CH–NH stretching region and the more variable fingerprint region, including the amide I and amide III bands that arise from coupled vibrations of the peptide backbone and reflect secondary structure. The discussion also addresses band fitting as a means of estimating relative amounts of secondary structure, while noting that published amide band assignments do not always agree.
6.
Author: Brian C. Smith
Continuing the series' study of carbonyl-containing polymers, this installment first reviews the infrared spectroscopy of the ester functional group and then applies it to several important polyesters, including polyethylene terephthalate (PET), one of the most economically important polymers in the world. Smith explains that esters display a memorable pattern of three intense peaks near 1700, 1200, and 1100 cm⁻¹, arising from the C=O stretch and two C–O stretches, which he calls the “Rule of Three.” The article also shows how the C=O stretching position distinguishes saturated esters, which appear near 1750 cm⁻¹, from aromatic esters, which fall between 1730 and 1715 cm⁻¹, and why the accompanying C–O peaks are needed to separate esters from other carbonyl compounds, such as ketones, that absorb in the same range.
7. Not attributable to a single manuscript (99 views): this entry was recorded against the bare LCGC North America journal-level DOI,
8.
Author: Douglas E. Raynie
Partition coefficients, expressed as log P or Kow, are frequently used to introduce and describe new extraction techniques and to develop new separation methods. In this installment of his sample preparation column, Raynie explains how an understanding of partition coefficients, together with diffusion, is needed to guide separation processes more completely. The column defines the most important forms of partition coefficients, including octanol–water partition coefficients (Kow) that describe lipophilicity or hydrophilicity, Henry's law constants, and soil or sediment distribution coefficients (Kd and the organic-carbon-normalized Koc), along with the assumptions behind them, such as the use of log D for ionizable species. It then illustrates how these equilibrium constants inform solvent selection in batch extractions and underpin modern microscale sorptive techniques, such as solid-phase microextraction (SPME) and stir-bar sorptive extraction (SBSE).
9.
Author: Brian C. Smith
This installment of Smith's polymer series examines pendant ester polymers, such as cellulose acetate, and polycarbonates. The article explains that acetate esters produce a distinctive, high-wavenumber C–C–O stretching peak near 1240 cm⁻¹, then turns to organic carbonates and shows how polycarbonates such as Lexan display three characteristic peaks arising from carbonyl, O–C–O, and O–C–C stretching vibrations. The discussion concludes by demonstrating how infrared spectroscopy can distinguish between different carbonate types and differentiate carbonates from esters based on peak position.
10.
Authors: Hongyan Chen and Hongda Yang
The authors used in situ, real-time attenuated total reflection Fourier transform infrared (ATR-FT-IR) spectroscopy to follow the synthesis of aspirin from salicylic acid and acetic anhydride with a sulfuric acid catalyst. The three-dimensional spectra showed clear changes in the position, shape, and intensity of the carbonyl bands of the reactants and products between 1830 and 1600 cm⁻¹. Principal component analysis (PCA) followed by target transformation was used to extract absorbance-versus-time trends for the raw materials and products, allowing reaction progress and the end point to be determined without separating or purifying the reaction mixture. The results showed that the sulfuric acid–catalyzed acetylation of salicylic acid is a complex but rapid, high-conversion reaction that proceeds in two stages with different rates, demonstrating the value of online ATR-FT-IR for process analysis and optimization.
References
(1) Leikin, S.; Phillips, A. ICP-OES as a Viable Alternative to ICP-MS for Trace Analysis: Meeting the Detection Limits Challenge. Spectroscopy 2023, 38 (10), 7–13.
(2) Smith, B. C. The Infrared Spectra of Polymers II: Polyethylene. Spectroscopy 2021, 36 (9), 24–29.
(3) Smith, B. C. Infrared Spectroscopy of Polymers XIII: Polyurethanes. Spectroscopy 2023, 38 (7), 14–16.
(4) Smith, B. C. The Infrared Spectra of Polymers III: Hydrocarbon Polymers. Spectroscopy 2021, 36 (11), 22–25.
(5) Adar, F. Interpretation of Raman Spectrum of Proteins. Spectroscopy 2022, 37 (2), 9–13, 25.
(6) Smith, B. C. Infrared Spectroscopy of Polymers, VIII: Polyesters and the Rule of Three. Spectroscopy 2022, 37 (10), 25–28.
(7) DOI:
(8) Raynie, D. E. Practical Understanding of Partition Coefficients. LCGC North America 2023, 41 (3), 95–98, 111.
(9) Smith, B. C. Infrared Spectroscopy of Polymers, IX: Pendant Ester Polymers and Polycarbonates. Spectroscopy 2022, 37 (11), 16–19, 31.
(10) Chen, H.; Yang, H. Online ATR-FT-IR for Real-Time Monitoring of the Aspirin Esterification Process in an Acid-Mediated Reaction. Spectroscopy 2022, 37 (S8), 7–12, 32.
Related to this article