Appendix VII: Mid-IR (FT-IR)

Author(s)Howard Mark

Additional information from the Mid-IR (FT-IR) section of the Pittcon Review article.

Manufacturer: Anasys Instruments

anasysinstruments.com

Product name: nanoIR

Infrared Spectrometer / AFM

New this year: New IR source with a larger laser tuning range

Used for: Lab analysis

Measurement Mode: Quantum Cascade laser using Transmission

Special features: laser tuning range of 900-2000 cm-1 and 2235-3600 cm-1 , the new QCL laser has a smaller line width of a Quantum Cascade Laser (QCL).

Suggested applications: Polymers including multilayers, blends, and thin films, biorenewable polymers, single particle analysis, pharmaceuticals, organic photovoltaics, life sciences, bio materials.

Primary benefits: Allows nanoscale analysis of materials using Infrared spectroscopy, increased coverage of the mid IR, chemically analyze thinner samples using the AFM cantilever, sample thickness down to 10 nm.

Unique features: High spatial resolution IR spectroscopy, simultaneous mechanical and chemical analysis, optional polarization control allowing molecular orientation studies.

Manufacturer: Block Engineering LLC

Blockeng.com

Product name: LaserTune

QCL tunable Mid-IR Source

New this year: Widest tuning range of any commercially off the shelf Mid-IR source, over 5-14 microns tuning range and <1 wavenumber accuracy, small footprint, fully integrated enclosure.

Used for: Lab QCL source, AFM and IR Spectroscopy integration, OEM integration

Portable, dimensions: 4 × 4 × 3 inch

Measurement Mode: Diffuse Reflection

Special Features: Widest tunable, Mid-IR source overf 5-14 microns wavelength range, small footprint, fully integrated QCL source, requires no external controllers or power supply to operate

Available as separate product, May be used in other equipment, Compatible with other manufacturers' equipment

Suggested applications: Integration into OEM systems, AFM and IR Microscope applications, Laboratory research

Primary benefits: Requires no external controllers or power supplies

Manufacturer: Blue Industry and Science

blueindustryandscience.com

Product name: Blue X-FLR8

Gas Monitoring Mid Infrared spectroscopy gas analyzer

New this year: Brand-new instrument

Used for: Lab, Process, Hand-held/portable applications

Dimensions: 420 × 310 × 175 mm

Measurement Mode: Photo Acoustic Spectrometry in a gas sample.

Special Features: Portable, battery powered multi-purpose gas analyzer for real-time measurements of trace gases.

Software: BlueSoftGas proprietary program package for control, analysis and display

Available as separate product, may be used in other equipment, compatible with other manufacturers' equipment

Suggested applications: leak detection, Indoor Air Quality, Environmental, Petrochemical, Gas generation, Rare/exotic gases monitoring, Exhaled Breath analysis, Forensics.

Primary benefits: real-time analysis by giving access of more gases, no sample preparation needed, very limited calibration, no consumables, easy portability.

Unique features: 300 gases quantifiable in real-time below 100 ppb, Partial list: hydrocarbons, amines, carbonyl compounds, alcohols, halogenated compounds, esters, chlorides, thiols, Can be tailored to your own needs.

Manufacturer: Bruker Corporation

brukeroptics.com

Product name: LUMOS

FTIR Spectrometer/ Microscope

Used for: Lab, Process analysis

Measurement Mode: Motorized ATR Crystal and IR measurements

Special Features: Stand-alone FT-IR microscope with full automation,10 year warranty on laser & interferometer, 5 year warranty on IR source

May be used in other equipment

Suggested applications: Material Science, Forensics, Mineralogy, Failure Analysis, Content Uniformity, Sample Homogeneity and Quality Control

Unique features: Designed to combine best performance for visible inspection and infrared spectral analysis with highest ease and comfort

Manufacturer: Durasens

durasens.com

Product name: LSP-T Series

FT-IR: Diamond ATR Analyzers

New this year: Hardware and software integrated sample temperature control

Used for Lab & Process analysis

Measurement Mode: ATR

Special Features: Analyzer with built-in diamond ATR sampling element, integrated chemometric software and temperature control

Software: Standard FTIR software plus integrated chemometric and temperature control software

Suggested applications: Composition verification, multicomponent analysis of samples in the food, beverage, pharmaceutical, chemical, petrochemical, and related industries.

Primary benefits: Easy, nondestructive way to quickly determine the chemical composition of liquids, emulsions, gels, pastes, and slurries under controlled temperatures.

Unique features: Compact, robust, easy to use multi-reflection diamond ATR FT-IR analyzers with integrated temperature control and custom PLS chemometrics. Only microliters of sample are required for analysis.

Manufacturer: Newport Corporation, Oriel Product Line

newport.com

Product name: MIR 8035 FT-IR Spectrometer

FTIR Spectrometer

New this year: New MIR8035 FT-IR Spectrometer

Used for: Lab, process

Accessory/component: Oriel's MIR 8035 supports most manufacturer's FTIR accessories. The software allows the import of libraries and supports most file formats.

Special features: modularity. Is suited for researchers who need to change detectors, sources, and beam splitters. Resolution of 0.5 cm1 is possible. Improved S/N compared to previous model.Also has a new commercially available software application – Essential FTIR.

Measurement Mode: Transmission, reflection, ATR

Software: Essential FTIR

Suggested applications: All common FTIR applications

Primary benefits and unique feature: The instrument's modularity. The detector, source and sample compartment are all modular components, and can be switched as application requirements change.

Manufacturer: PAIR Technologies

pairtech.com

Product name: PAIR Series 100

Mid Infrared Rapid Scan Spectrometer

New this year: Acquisition of spectra in the finger print region at >1000 scans per second.

Used for: Lab, process

Compatible with other manufacturers' equipment.

Suggested applications: Reaction monitoring, kinetics, process monitoring, process control and quality, combustion process monitoring

Primary benefits: No nitrogen purge required, Can obtain data that is missed with an FT-IR, Potential to save significant amount of lab time, rugged: reduced sensitivity to vibration and environmental changes than FT-IR, Simultaneous dual channels

Unique features Scans rates in excess of 1000 scans/second, True dual beam system.

Manufacturer: Precisive, LLC

precisive-instruments.com

Product name: PRECISIVE 5

Process & pipeline analyzer

New this year: Unique all-optical, real-time, on-line hydrocarbon composition monitoring platform.

Used for: Process analysis

Measurement Mode: Infrared Absorption

Special Features: Multi-component trace hydrocarbon/VOC analyzer, (certified for hazardous-areas with NEMA4X, CSA Class1Div2, ATEX Zone 2, IECEx, and CE compliance) MTFS platform (multiplexed tunable filter spectrometer), real-time measurements with equivalent accuracy and repeatability of a GC, permanent calibration, completely unattended remote operation, lower cost of installation, operation and maintenance comparable to GC and FTIR instruments. See

http://www.precisive-instruments.com/sites/default/files/pdf/precisive-5-press-release.pdf

Software: Modbus register map provided, and UI can also be provided at no cost.

May be used in other equipment, compatible with other manufacturers' equipment

Suggested applications: natural gas, LNG, LPG, BOG, biogas and flare monitoring, wherever fast-response hydrocarbon composition analysis is required, metering and custody transfer (BTU, Wobbe, calorific value), hydrocarbon processing and petrochemical applications, combustion and emission monitoring

Primary benefits: 1 second response for up to 10 components hydrocarbon composition, excellent stability and linearity, a compelling cost/benefit alternative to G.C.

Unique features: No concerns over the supply of helium.

Manufacturer: Thermo Fisher Scientific

thermofisher.com

Product name: Thermo Scientific Nicolet iS 50

FT-IR spectrometer

New this year: One-touch operation allows switching between multiple experiments, Multiple sampling stations on one instrument, Sample compartment FT-Raman accessory, Built-in, mid/far-IR diamond ATR module, Automated beamsplitter exchanger, Triple detector housing allows, Near-IR module with integrating sphere and fiber optics, Mercury TGA software for one-click analysis of full TGA-IR runs, Mercury GC software for one-click analysis of GC-IR runs

Used for: Lab, process analysis

Measurement Mode: ATR, Transmission, Reflection, Raman, NIR, GC-IR, TGA-IR

Specialty accessory description: The modules for the Nicolet iS50 FT-IR are field upgradeable. Move from a basic FT-IR bench unit to a full workstation with beamsplitter automation, diamond ATR, Raman

Features: Research-grade FT-IR spectrometer, diamond ATR, Raman, and NIR modules, spectra from the far-infrared to the visible range, seals for optimal purging or seal/desiccated operation, OMNIC Software plus MacrosBasic, "hands-off" operation, Efficient vibration isolation, No top panel air vents, Externally mounted laser permits maintenance

Software: Available as separate product, 21CFR11 compliant, cGMP compliant, May be used in other equipment, Compatible with other manufacturers' equipment

Suggested applications: Material identification, characterization, and quantitation for Forensics, Pharmaceuticals, Paints, Inks, Dyes, Inorganic analysis via far-IR ATR, Color analysis, Polymers, General Analytical Laboratories, Art Conservation, Oil and Gas, Solvents, Silicon Wafer research

Primary benefits: Simplified operation including automation for unattended operation, Multi-spectral range analysis, Software developed to enable unskilled users to get results, Mercury TGA for deformulation, Mercury GC for analysis of separations, Automatic analysis and report building after data collection. Automatic storage of results for recall, Full integration of hardware and software

Unique features: multiple techniques on one instrument, FT-Raman with x-y-z stage, Single point, mapping or arrays, built-in diamond ATR, mid and far infrared data collection in one sample station, automatic beamsplitter changer, mercury GC and mercury TA analytical software for one-click analysis 55,000:1 signal-to-noise ratios with no adjustments

Manufacturer: Wilks Enterprise, Inc.

WilksIR.com

Product name: InfraCal 2

Filter-based infrared analyzer

New this year: The new InfraCal 2 Analyzers combine improved electronics with a touch screen intuitive display that includes many new features.

Used for: Lab, process, handheld analysis

Portable, dimensions: 6.7" (17 cm) × 7.8" (19.8 cm) × 5.2" ( 13.2 cm ), 5.8 lbs. (2.6 kg)

Measurement Mode: Transmission, ATR

Special Features: portability with optional internal battery pack, touch screen display, multiple calibrations, ability to measure 2 analytical and 1 reference or 1 analytical and 2 reference wavelengths, internal data logging, alarm functions, password protection, data transfer capabilities, internal data logging, alarm functions, password protection, data transfer capabilities, and internal battery pack, no moving parts. On-site measurements using the InfraCal 2 Analyzer typically take from one to 10 minutes Available as separate product.

Suggested applications: Sub-ppm detection of oil in water, cleaning of metal parts, barrier layer thickness in flexible films, textile and fiber finishes, quality control testing, virtually any IR quantitative measurement that needs to be done easily, routinely, economically – on site or in the lab

Primary benefits: Can be used by a non-spectroscopist for routine measurements, freeing up the lab technicians as well as lab equipment. Quick turn-around—measurements in under a minute. Analysis can be moved to production area, loading dock or remote site.

Unique features: No moving parts makes it rugged and portable

Articles in this issue

over 13 years ago

Appendix XIV: X-Ray

over 13 years ago

Appendix IV: Fluorescence

over 13 years ago

Appendix XII: Terahertz

over 13 years ago

Appendix II: Atomic Spectroscopy

over 13 years ago

Market Profile: Biophotometers

over 13 years ago

Appendix X: Raman

over 13 years ago

Products

Related to this article

Pittsburgh, Pennsylvania, USA. Beautiful Pittsburgh at twilight. | Image Credit: © checubus - stock.adobe.com
Organized by CPACT, the April 27 to 29 meeting at the Marriott Pittsburgh City Center will bring together scientists, engineers, and vendors across the process industries, with keynotes on PAT, Raman, and NIR applications and an abstract deadline of December 7, 2026.
Abstract concept of connecting molecules DNA network vector neurons | Image Credit: © bill2499 - stock.adobe.com
Garth Simpson of Purdue University outlines plans to survey more ordered molecular assemblies and to apply interface-specific chiral spectroscopy to enzyme reactors, solid-phase synthesis, spin-selective reactions, and, ultimately, a new analytical method.
Curated 2026 Evergreen Content from Spectroscopy. ©  Chanakarn -chronicles-stock.adobe.com
Spectroscopy's editors gather 143 evergreen articles from 2026, including tutorials, terminology guides, technique reviews, application surveys, peer-reviewed research and the magazine's long-running columns, and organize them by subject so readers can build lasting knowledge one topic at a time.