What Spectroscopists Should Be Thankful For This Year
Key Takeaways
- Miniaturized spectroscopy improved field utility, exemplified by smartphone-integrated third-generation Raman and expanding handheld FT-IR and SERS applications for ultra-trace drugs and food adulterants.
- Clinical Raman translation advanced, with handheld 785-nm ex vivo skin spectra achieving ~77.8% sensitivity and ~77.7% specificity, underscoring promise alongside the need for rigorous validation.
Smaller instruments, smarter data tools, and new ways to measure at the sample all helped the field this year.
With Thanksgiving coming up tomorrow, it’s worth looking back on 2026. This was a year that started out uncertain on the spectroscopy front. How was the market going to look? What new advances in instrumentation were going to take shape? When 2026 started, the field was combatting significant economic pressures, widening skills gaps, and notable uncertainty regarding
The Miniaturization of Instruments
To start off, spectroscopists should be thankful for the continued miniaturization of spectroscopic instruments. These instruments have allowed spectroscopists to conduct their analysis on site without moving the samples to a traditional laboratory environment. Both convenience and accuracy of these tools improved. As an example, the newest third-generation Raman units hand their data system off entirely to a paired smartphone.2 That brings the instruments down to about 6 cm long and 63 g without giving up field-usable signal-to-noise.2
Meanwhile, applications grew along with the shrinking hardware.
Clinical uses advanced too. Researchers at Florida Atlantic University used a mobile 785-nm handheld Raman platform to collect nearly 1,000 ex vivo spectra from normal tissue and from basal cell and squamous cell carcinoma samples.4 Their
AI as a Partner in Interpretation
As mentioned above, AI usage is one of the ongoing challenges facing the industry. In Spectroscopy’s State of the Industry survey, nearly 41% of respondents said they were most excited about AI and analytics changing how data are interpreted, and 27% pointed to miniaturized, field-deployable devices.5 Among instrumentation trends, portable and handheld analyzers (56.9%) and AI-driven data analysis tools (52.9%) drew the most interest.5
In addition, generative methods are drawing greater interest. Variational autoencoders, generative adversarial networks, and transformer models are being used to fill in scarce labeled data, generate physically plausible spectra, and work backward from a spectrum to a molecular structure.6 This topic also anchored the James L. Waters Symposium at
Advancements in Raman Instrumentation
The versatility and popularity of Raman spectroscopy continues to grow, and this should excite users. 2026 was marked by several Raman hardware upgrades. As an example, spatial heterodyne offset Raman is replacing slit-limited dispersion with grating interferometry, giving roughly 10-fold gains in sensitivity in a compact design with no moving parts.9 The International Conference on Raman Spectroscopy (ICORS) 2026 in Istanbul, Turkey, also highlighted more advancements in Raman instrumentation and methods. Numerous speakers highlighted coherent and ultrafast Raman methods that track reactions, phase transitions, and drug distribution in situ.10
Bringing the Lab to the Sample
Several meetings this year focused on taking spectroscopy out of the laboratory. At the 2026 SciX Conference in Sparks, Nevada, several talks covered moving biophotonic and vibrational spectroscopic methods from the bench into clinical and industrial workflows.11 Earlier in the year, at the
Behind all of these advances are the people doing the work: the researchers who present at conferences, the instrument developers who keep shrinking and sharpening their designs, and the analysts who check results before anyone acts on them. To everyone who shared their work with Spectroscopy in 2026, thank you. Happy Thanksgiving!
References
- Wetzel, W. Looking Ahead at 2026: The Biggest Trends in Spectroscopy. Spectroscopy Online, 2026.
https://www.spectroscopyonline.com/view/looking-ahead-at-2026-the-biggest-trends-in-spectroscopy (accessed November 17, 2026). - Workman, J., Jr. Pocket-Sized Power: How Handheld Spectroscopy Is Putting the Laboratory in Every Hand. Spectroscopy Online, 2026.
https://www.spectroscopyonline.com/view/pocket-sized-power-how-handheld-spectroscopy-is-putting-the-laboratory-in-every-hand (accessed November 17, 2026). - Wetzel, W. The Rise of Portable and Handheld Spectroscopy. Spectroscopy Online, 2026.
https://www.spectroscopyonline.com/view/the-rise-of-portable-and-handheld-spectroscopy (accessed November 17, 2026). - Wetzel, W.; Spectroscopy Staff. Separating Skin Cancer From Normal Tissue Using Handheld Raman Spectroscopy. Spectroscopy Online, 2026.
https://www.spectroscopyonline.com/view/separating-skin-cancer-from-normal-tissue-using-handheld-raman-spectroscopy (accessed November 17, 2026). - Hroncich, C. State of the Industry: Spectroscopy at a Crossroads. Spectroscopy Online, 2026.
https://www.spectroscopyonline.com/view/state-of-the-industry-spectroscopy-ai-automation-pharma-biotech-materials (accessed November 17, 2026). - Workman, J., Jr. Artificial Intelligence in Spectroscopy: A Summary of Spectroscopy Magazine’s Coverage, 2024–2026. Spectroscopy Online, 2026.
https://www.spectroscopyonline.com/view/artificial-intelligence-in-spectroscopy-a-summary-of-spectroscopy-magazine-s-coverage-2024-2026 (accessed November 17, 2026). - Workman, J., Jr. Generative Artificial Intelligence in Spectroscopy: Extending the Foundations of Chemometrics. Spectroscopy Online, 2026.
https://www.spectroscopyonline.com/view/generative-artificial-intelligence-in-spectroscopy-extending-the-foundations-of-chemometrics (accessed November 17, 2026). - Workman, J., Jr. Artificial Intelligence as the Next Layer of Chemometrics. Spectroscopy Online, 2026.
https://www.spectroscopyonline.com/view/artificial-intelligence-as-the-next-layer-of-chemometrics (accessed November 17, 2026). - Workman, J., Jr. Small Chips, Deep Signals: The Quiet Reinvention of Raman Instrumentation. Spectroscopy Online, 2026.
https://www.spectroscopyonline.com/view/small-chips-deep-signals-the-quiet-reinvention-of-raman-instrumentation (accessed November 17, 2026). - Popp, J. From Better Spectra to Better Decisions: Five Trends Highlighted at ICORS 2026. Spectroscopy Online, 2026.
https://www.spectroscopyonline.com/view/from-better-spectra-to-better-decisions-five-trends-highlighted-at-icors-2026 (accessed November 17, 2026). - Wetzel, W.; Spectroscopy Staff. What Were Some of the Key Topics Discussed at SciX 2026? Spectroscopy Online, 2026.