How Four Determination Factors Strengthen Blinking-Based Dye Identification
In this interview clip, Kristin L. Wustholz of William & Mary explains how her group judges the fidelity of its blinking-based classifications, why real artworks will call for classification libraries, and where the method fits alongside SERS.
As part of our coverage of the Eastern Analytical Symposium (EAS), Kristin L. Wustholz, a Margaret Hamilton Professor and Department Chair of Chemistry at William & Mary, discussed how her group evaluates its blinking-based dye classifications, what it will take to apply the approach to real artworks, and where the method fits alongside
Rather than rely on a single headline figure such as 90% accuracy, Wustholz’s team tested each classification against four determination factors. Some classifications met all four criteria, while others met only one or two, which is a spread Wustholz says reveals how much confidence each result deserves. With the possible exception of minimum accuracy, no single metric was sufficient on its own, so the group adopted all four as a stricter, more robust standard. A sample that passes the full set is more likely to represent a positive or exclusive identification of the analyte.
Wustholz described her team’s published work as a starting point for future research. Her team’s study focused on rhodamine dyes and BIC ink, a relatively simple matrix, using the kind of solvent swab conservators already rely on. Real objects will introduce far more variability. To address that, she expects to build what amounts to a classification library rather than a
Wustholz sees blinking-based classification as complementary to SERS. SERS remains the gold standard in certain cases, performing especially well for cationic dyes and strongly absorbing fluorophores such as rhodamines and anthraquinones. Blinking may have the edge when analysts face subtle differences among natural pigments or a true unknown, since it could require smaller samples and be less invasive than removing material from an object. She says the two techniques offer different routes to the same question: what are the fading dyes and pigments in works of art?