Tutorial Tuesday: When to Use Infrared Spectroscopy

In this “Tutorial Tuesday” clip, Peter Larkin, who is a Manager of Spectroscopy, Thermal Analysis, and Chromatography at Syensqo, highlights how people use the method or technique that they are comfortable with, even if it’s not the best one to use.

In this “Tutorial Tuesday” clip, Peter Larkin, who is a Manager of Spectroscopy, Thermal Analysis, and Chromatography at Syensqo, highlights how people use the method or technique that they are comfortable with, even if it’s not the best one to use. Instead, Larkin explains how despite encountering instances where using infrared (IR) spectroscopy would be more effective, analytical chemists continue to insist on using other techniques.

Below is a transcript of Larkin’s remarks, which address why analytical chemists don’t necessarily know when to use IR spectroscopy. His comments were part of a longer panel discussion, which can be viewed here or in the literature.1,2

Peter Larkin: Even in many organizations, unless you have an experienced analytical chemist, which in my world are worth their weight in gold, they don't necessarily understand when to use IR and when to use other techniques. Everybody goes through their favorite toolbox and their favorite tool, but it's not necessarily the best tool. I'd put it that simply.

So we had a problem come in, and at the end of the day, it was 2-ethylhexyl tails. Any time you see tails, you immediately think it's going to be a number of things. And it was for a registration document, and we had to do an analysis for it. That means it can't be above one percent. However, this was from another vendor. It's actually a formulation.

The person that was coordinating this was an NMR spectroscopist. They did NMR. And there were an awful lot of peaks telling it was a complex formulation. This is a great application for infrared (IR) spectroscopy. You could just quickly do a library search. In this case, you could quickly just look at it by eye if you had training and say, "It's got this, this, and this, and about how much."

References
  1. Wetzel, W. Previewing a SpecAcademy Roundtable Discussion. Spectroscopy Online, 2026. https://www.spectroscopyonline.com/view/previewing-a-specacademy-roundtable-discussion (accessed September 25, 2026).
  2. Miseo, E.; Carrabba, M.; Larkin, P. J.; D’Agostino, J.; de Haseth, J.; Wetzel, W. The Mismatch Between Education and Industry. Spectroscopy Online, 2026. https://www.spectroscopyonline.com/view/the-mismatch-between-education-and-industry (accessed September 25, 2026).

Related to this article

Optical and Electronic Instrument Components,  ©  ridwan -chronicles-stock.adobe.com
The updated and expanded 2026 edition of Spectroscopy's Instrument Components Terminology Guide defines the sources, detectors, optical and dispersive elements, sampling hardware, physical constants, and unit conversions used across UV-vis, NIR, IR, Raman, X-ray, and atomic spectroscopic instrumentation, with new terms reflecting component developments reported between 2022 and 2026.
Curated 2026 Evergreen Content from Spectroscopy. ©  Chanakarn -chronicles-stock.adobe.com
Spectroscopy's editors gather 143 evergreen articles from 2026, including tutorials, terminology guides, technique reviews, application surveys, peer-reviewed research and the magazine's long-running columns, and organize them by subject so readers can build lasting knowledge one topic at a time.
Highly Substituted Benzene Rings—The Rest of the Story II: Spectra
This column, the second installment on highly substituted benzene rings, shows that tri- and tetra-substituted substitution patterns can be distinguished by whether the ring-bending peak is present and by the position of the in-phase aryl C-H wagging peak, which shifts according to how many adjacent hydrogens the ring carries.
Spectral Frontiers: Seeing the Unseeable Microspectroscopy
Microspectroscopy, the marriage of spectroscopic chemical identification with microscopic spatial resolution, has advanced from Perkin-Elmer's first commercial infrared microspectrometer in 1953 to today's nanoscale AFM-IR probes, synchrotron-brightness infrared beamlines, and compact hyperspectral tissue imaging devices being developed for AI-assisted cancer detection.
Mapping Molecular Mobility Pixel by Pixel
Garth Simpson of Purdue University explains how patterned photobleaching and spatial Fourier transforms can turn a single-point measurement into a diffusion coefficient at every pixel in the field of view.