Ultrafast Laser Diagnostics

Author(s)Avantes

Even though no current electronics is fast enough to measure femtosecond lasers, an estimation of the pulse duration, peak wavelength, and relative intensity is possible.

Even though no current electronics is fast enough to measure femtosecond lasers, an estimation of the pulse duration, peak wavelength, and relative intensity is possible.

The femtosecond time scale is out of reach for even the fastest electronics, so to perform pulse diagnostics other measurement techniques need to be used.

The AvaSoft-Femto add-on turns your Avantes spectrometer into a femtosecond laser diagnostic tool that can provide you with an estimation of the transform limited pulse duration as well as measuring the peak wavelength and relative intensity of the laser output. Using the add-on users can also easily export the measurements to spread sheet programs like Microsoft Excel for record keeping or further analysis.

Many femtosecond mode-locked lasers can generate nearly bandwidth-limited pulses, especially when they are based on soliton mode locking. A femtosecond mode-locked Ti:Sapphire laser when fully optimized propagates a soliton-like pulse with a hyperbolic secant squared function intensity distribution in the frequency domain.

Figure 1: An AvaSpec-2048L is used for femtosecond laser measurements.

By accurately measuring the spectral output of a femtosecond mode-locked Ti:Sapphire and using the time-bandwidth product of different pulse shapes (Gaussian, Hyperbolic Secant Squared, Lorentzian) the lower limit for the pulse duration can be determined.

FWHM Measurement

The full-width at half maximum (FWHM) is accurately measured using an Avantes spectrometer and this is then used in combination with a value of K (that is dependent on the symmetrical shape of the pulse) to calculate the transform limited pulse duration;

ΔvΔt≥K

The AvaSoft-Femto software allows for a quick and convenient way to show the transform limited pulse duration according to the pulse shape selected in the software. The complete Femto package also provides a good general purpose spectrometer that can be used for various applications in the lab.

Table I: Values for K depending on the pulse shape.

When using AvaSoft-Femto with an Avantes spectrometer that doesn't have an order sorting filter installed, you can also use the system to measure laser lines in the ~300–600 nm range by observing them in the second order. This means 500 nm will show up as 1000 nm on the spectrometer. Lines in the ~200–300 nm range can be seen in the third order (that is, 300 nm will show up at 900 nm on the spectrometer). The spectrometer included in the Ava-Femto package can be used for second and third order measurements.

Typical Configuration for AvaSoft-Femto

The AvaSoft-Femto can be used with virtually any existing Avantes spectrometer provided it covers the required wavelength range.

Avantes

Oude Apeldoornseweg 28, 7333 NS Apeldoorn, The Netherlands

tel. +31 313 670 170

Email: info@avantes.com; Website: www.avantes.com

Articles in this issue

almost 13 years ago

PIKE Technologies

almost 13 years ago

Amptek, Inc.

almost 13 years ago

Ocean Optics

almost 13 years ago

Photonis USA

almost 13 years ago

Shimadzu Scientific Instruments

almost 13 years ago

Milestone, Inc.

almost 13 years ago

Savillex Corporation

almost 13 years ago

WITec GmbH

Related to this article

Abstract concept of connecting molecules DNA network vector neurons | Image Credit: © bill2499 - stock.adobe.com
Garth Simpson of Purdue University outlines plans to survey more ordered molecular assemblies and to apply interface-specific chiral spectroscopy to enzyme reactors, solid-phase synthesis, spin-selective reactions, and, ultimately, a new analytical method.
Curated 2026 Evergreen Content from Spectroscopy. ©  Chanakarn -chronicles-stock.adobe.com
Spectroscopy's editors gather 143 evergreen articles from 2026, including tutorials, terminology guides, technique reviews, application surveys, peer-reviewed research and the magazine's long-running columns, and organize them by subject so readers can build lasting knowledge one topic at a time.