Glass Expansion

Company Description

Glass Expansion has been manufacturing sample introduction components for ICP emission and mass spectrometers since the early 1980s. Today we support both new and old instruments for 16 different manufacturers, representing sample introduction systems for over 50 different ICP-AES and ICP-MS models. Glass Expansion has developed unique and proprietary manufacturing methods, which have resulted in the production of components of high mechanical strength and micron-level dimensional accuracy to satisfy the narrowest of analytical specifications, each and every time. Our products are recognized worldwide for their excellent precision, cost-effectiveness, and reproducibility of results.

Chief Spectroscopic Techniques Supported

  • ICP-AES

  • ICP-MS

Markets Served

Glass Expansion's products are used widely in private and government analytical laboratories within agricultural, environmental, food, forensic, geological, metallurgical, petrochemical, and pharmaceutical industries. We support leading ICP models including Thermo Fisher, PerkinElmer, Teledyne Leeman, Agilent, SPECTRO Ametek, and Horiba J-Y. Whether you need just a nebulizer, a complete sample introduction system, or the answer for a tricky sample, we have the innovative, high-quality products and applications expertise to assist.

Major Products/Services

Nebulizers

  • SeaSpray - High dissolved solids nebulizer

  • MicroMist - Low uptake nebulizer for all ICPs

  • Conikal - An industry standard

  • Slurry - For slurries and suspensions

  • DuraMist - Routine high-precision HF analyses

  • OpalMist - Ideal for geochemistry and semiconductor industry

  • VeeSpray - Handles high particle and TDS loads best

Spray Chambers

  • Tracey Cyclonic - An industry standard

  • Twister Cyclonic - Reduces solvent load

  • Cinnabar Cyclonic - Low-volume spray

  • IsoMist programmable temperature spray chamber

Torches

  • Fully demountable D-torches

  • Semi-demountable torches

  • Fixed quartz torches

RF Coils

Replacement RF coils with optional silver or gold coating.

Accessories

  • ICP-MS cones

  • Nickel and platinum interface cones for all major ICP-MS models.

  • Niagara Plus and Assist – Enhanced productivity accessories

  • Capricorn – Argon humidifier

  • TruFlo – Sample uptake monitor

Facilities

Today, Glass Expansion has two global offices located in Australia and the United States. Between our two offices and network of distributors, we service every region of the globe, 24 hours a day. This ensures you receive a rapid response and timely order deliveries each and every time.

Glass Expansion
4 Barlows Landing Road
Unit #2A
Pocasset, MA 02559

TELEPHONE
(508) 563-1800
(800) 208-0097

FAX
(508) 563-1802

E-MAILgeusa@geicp.com

WEB SITEwww.geicp.com

YEAR FOUNDED
1985


Related to this article

Spectroscopy Top 10 DOI Articles of the Month (October 2026)
The following articles are the most accessed digital object identifier (DOI) manuscripts for Spectroscopy and LCGC International during the month of October 2026. Nine articles are individually ranked here by DOI page views; the seventh-highest entry (99 views) was recorded against the bare LCGC North America journal-level DOI rather than an individual article and is therefore not attributable to a single manuscript.
Mapping Molecular Mobility Pixel by Pixel
Garth Simpson of Purdue University explains how patterned photobleaching and spatial Fourier transforms can turn a single-point measurement into a diffusion coefficient at every pixel in the field of view.
Optical and Electronic Instrument Components,  ©  ridwan -chronicles-stock.adobe.com
The updated and expanded 2026 edition of Spectroscopy's Instrument Components Terminology Guide defines the sources, detectors, optical and dispersive elements, sampling hardware, physical constants, and unit conversions used across UV-vis, NIR, IR, Raman, X-ray, and atomic spectroscopic instrumentation, with new terms reflecting component developments reported between 2022 and 2026.