Savillex Corporation

Savillex Corporation

Company Description

Savillex Corporation has been manufacturing fluoropolymer laboratory products since 1976 and has unmatched expertise in the molding and machining of fluoropolymers — especially PFA. Because all of our design, tooling, molding, manufacturing, assembly, and testing is done in-house, we have complete control of product quality. Our products are widely used in trace metals analysis — from sample collection and preparation through to sample introduction.

Chief Spectroscopic Techniques Supported

Our ICP sample introduction systems and products are manufactured from PFA using the highest purity grades of PFA resin, and historically have been focused on ICP-MS. More recently we have been developing unique new products for ICP-OES, applying the advantages of PFA to the ICP-OES application challenges of high solids and high particulate samples. The sample introduction system is a critical component of both ICP-OES and ICP-MS instruments.

The design of the sample introduction system affects all aspects of performance, including sensitivity, stability, washout, memory, matrix tolerance, sample compatibility, and also oxide level and isotope ratio precision in the case of ICP-MS. In addition, the purity of the materials that come into contact with the sample directly impact the level of the analytical blank. With over 35 years experience in fluoropolymer molding and unmatched expertise in the design and molding of PFA components for trace metal analysis, Savillex is bringing new capabilities to ICP-MS and ICP-OES.

Markets Served

Initially focused on semiconductor applications, Savillex sample introduction systems are being applied to a wide range of ICP-MS and ICP-OES applications including environmental, geochemistry, biomedical, and petrochemical.

Major Products/Services

C-Flow PFA microconcentric nebulizers

  • From 200 µL/min down to 35 µL/min uptake rate

  • High sensitivity, low RSDs

  • Unique two-piece body design ensures excellent reproducibility from nebulizer to nebulizer

  • Easily backflushed without tools

  • Constant ID sample uptake path

C-Flow 700d PFA nebulizer

  • 0.2 mL/min to 1.2 mL/min uptake rate (pumped)

  • Extreme matrix tolerance: up to 25% salt and 80 µM diameter particulates

  • Easily backflushed without tools

  • Removable uptake line with Savillex zero dead volume connector for complete flexibility

  • Suitable for routine applications of both ICP-MS and ICP-OES

X-Flow PFA nebulizer

  • Ultimate matrix tolerance: virtually uncloggable

  • One piece all PFA design — no metal or ceramic orifices

  • Removable uptake line with Savillex zero dead volume connector for complete flexibility

PFA Inert Kits

  • True double pass Scott type design

  • O ring free end cap

  • Efficient removal of large droplets — equally applicable to semiconductor and high matrix sample types

  • Platinum or sapphire injectors

Facility

Based in Eden Prairie, Minnesota, we serve thousands of customers in over 60 countries worldwide through our partners and distributors.

Savillex Corporation

10321 West 70th Street

Eden Prairie, MN 55344

TELEPHONE

(952) 935-4100

FAX

(952) 936-2292

E-MAIL

info@savillex.com

WEB SITE

www.savillex.com

YEAR FOUNDED

1976

Articles in this issue

almost 14 years ago

Agilent Technologies

almost 14 years ago

EDAX Inc.

almost 14 years ago

Moxtek, Inc.

almost 14 years ago

Glass Expansion

almost 14 years ago

PANalytical, Inc.

almost 14 years ago

Shimadzu Scientific Instruments

almost 14 years ago

Rigaku Corporation

almost 14 years ago

Amptek, Inc

almost 14 years ago

Ocean Optics

almost 14 years ago

International Crystal Laboratories

Related to this article

Monitoring Sugar Consumption and Ethanol Production During Yeast Fermentation Using a Raman Plate Reader and Multivariate Analysis
This column shows that a Raman plate reader paired with partial least squares regression can simultaneously quantify glucose, fructose, sucrose, and ethanol in yeast fermentation samples, using turbidity-matched calibration standards to correct for yeast-induced turbidity, and offers a rapid, label-free, high-throughput method for tracking sugar consumption and ethanol production in strain screening, media optimization, and process development.
Highly Substituted Benzene Rings—The Rest of the Story II: Spectra
This column, the second installment on highly substituted benzene rings, shows that tri- and tetra-substituted substitution patterns can be distinguished by whether the ring bending peak is present and by the position of the in-phase aryl C-H wagging peak, which shifts according to how many adjacent hydrogens the ring carries.
Healthcare administrator reviewing an insurance policy schedule with a stethoscope on a clipboard, health insurance coverage, medical underwriting, prior authorization, and patient claims processing. | Image Credit: Joi_studio - stock.adobe.com
In a SciX interview, Marc Porter covered a lot of ground, from a student-driven pivot into immunoassays to a baseball analogy for Stokes and anti-Stokes scattering, and shares the open questions he is still chasing.