Savillex Corporation

Company Description

Savillex Corporation has been manufacturing fluoropolymer laboratory products since 1976 and has unmatched expertise in the molding and machining of PFA. All our design, tooling, molding, manufacturing, and testing is done in-house, giving us complete control of product quality. Our products are widely used in trace metals analysis-from sample collection through to ICP sample introduction.

Chief Spectroscopic Techniques Supported

The sample introduction system is a critical component of both ICP-OES and ICP-MS instrumentation. The design of the sample introduction system affects all aspects of performance, including sensitivity, stability, washout, matrix tolerance, and also oxide level and isotope ratio precision in ICP-MS. Also, the cleanliness of the materials that come into contact with the sample directly impact the quality of the analytical blank. Our ICP sample introduction products are manufactured using the highest purity grades of PFA resin. With over 40 years experience in fluoropolymer molding and unmatched expertise in the design and molding of PFA components, Savillex is bringing new products and capabilities to ICP-MS and ICP-OES, including the world's first blow molded PFA cyclonic spray chamber.

Markets Served

Savillex sample introduction systems are used across a wide range of ICP-MS and ICP-OES applications including semiconductor, geochemistry, pharmaceutical, environmental, biomedical, and petrochemical.

Major Products/Services

C-Flow PFA Microconcentric Nebulizers

  • From 200 µL/min down to 35 µL/min uptake rate

  • High sensitivity, low RSDs

  • Unique two-piece body design ensures excellent reproducibility from nebulizer to nebulizer

  • Easily backflushed without tools

  • Constant ID sample uptake path

C-Flow d-Type PFA Nebulizers

  • With removable uptake line

  • From 0.2 mL/min to 1.2 mL/min uptake rate (pumped)

  • Extreme matrix tolerance: up to 25% salt and 80 µM diameter particulates

  • Easily backflushed without tools

  • Suitable for routine applications of both ICP-MS and ICP-OES

X-Flow PFA Nebulizer

  • Ultimate matrix tolerance: virtually uncloggable

  • One piece all PFA cross-flow design

  • Removable uptake line with Savillex zero dead volume connector

PFA Cyclonic Spray Chamber

  • World's first blow molded cyclonic spray chamber

  • All PFA with interchangeable exit ports to suit different ICP instruments

  • Unmatched sensitivity for an inert cyclonic

  • Translucent side walls allow user to see inside during operation

PFA Inert Kits

  • True double pass Scott type design

  • O-ring free end cap

  • Used as OEM equipment

  • Platinum or sapphire injectors

Facility

Based in Eden Prairie, Minnesota, we serve thousands of customers in over 60 countries worldwide through our partners and distributors.

Savillex Corporation
10321 West 70th Street
Eden Prairie, MN 55344-3446

TELEPHONE
(952) 935-4100

FAX
(952) 936-2292

E-MAILinfo@savillex.com

WEB SITEwww.savillex.com

YEAR FOUNDED
1976

Articles in this issue

almost 9 years ago

The Humble Instrument Logbook?

almost 9 years ago

Avantes, Inc.

almost 9 years ago

Amptek, Inc.

almost 9 years ago

Alluxa, Inc.

almost 9 years ago

ABB Measurement & Analytics

almost 9 years ago

EDAX, Inc.

almost 9 years ago

Edinburgh Instruments

Related to this article

Monitoring Sugar Consumption and Ethanol Production During Yeast Fermentation Using a Raman Plate Reader and Multivariate Analysis
This column shows that a Raman plate reader paired with partial least squares regression can simultaneously quantify glucose, fructose, sucrose, and ethanol in yeast fermentation samples, using turbidity-matched calibration standards to correct for yeast-induced turbidity, and offers a rapid, label-free, high-throughput method for tracking sugar consumption and ethanol production in strain screening, media optimization, and process development.
Highly Substituted Benzene Rings—The Rest of the Story II: Spectra
This column, the second installment on highly substituted benzene rings, shows that tri- and tetra-substituted substitution patterns can be distinguished by whether the ring bending peak is present and by the position of the in-phase aryl C-H wagging peak, which shifts according to how many adjacent hydrogens the ring carries.
Healthcare administrator reviewing an insurance policy schedule with a stethoscope on a clipboard, health insurance coverage, medical underwriting, prior authorization, and patient claims processing. | Image Credit: Joi_studio - stock.adobe.com
In a SciX interview, Marc Porter covered a lot of ground, from a student-driven pivot into immunoassays to a baseball analogy for Stokes and anti-Stokes scattering, and shares the open questions he is still chasing.