
Executive Summary
Learn how careful selection of a HP-SIS can help your laboratory achieve optimum analytical performance and reduce operating costs with your inductively coupled plasma-optical emission spectroscopy (ICP-OES).

Executive Summary
Learn how careful selection of a HP-SIS can help your laboratory achieve optimum analytical performance and reduce operating costs with your inductively coupled plasma-optical emission spectroscopy (ICP-OES).

Webcast
Aired: Wed, Dec 14, 2022 2:00 PM EST This event is now available on demand.

Sponsored Content
Highlight of the superior performance achieved with a dedicated aqueous, high-performance sample introduction system (HP-SIS) from Glass Expansion.

Sponsored Content

Sponsored Content


Sponsored Content

Sponsored Content


Sponsored Content
Highlight of the superior performance achieved with a dedicated HF-resistant, high-performance sample introduction system (HP-SIS) from Glass Expansion.

Sponsored Content
Highlight of the superior performance achieved with a dedicated HF-resistant, high-performance sample introduction system (HP-SIS) from Glass Expansion.

Sponsored Content
Peltier Cooled Cyclonic Spray Chamber Kit, compatible with Agilent® 7900 and 8900 and legacy Agilent® ICP-MS models, provides improved washout, increased sample throughput.

Sponsored Content
Tuesday, October 26, 2021 at 11am EDT| 8am PDT| 4pm BST| 5pm CEST

Sponsored Content
Glass Expansion’s Peltier Cooled Cyclonic (PCC) Spray Chamber Kit is fully compatible with the Agilent® 7900 and 8900, and with the legacy Agilent® ICP-MS models.

Sponsored Content
Glass Expansion has developed an apparatus for Bacterial Filtration Efficiency (BFE) testing of surgical masks based upon EN 14683 and ASTM F2101 test methods.

Sponsored Content
Glass Expansion’s ConstantTorque™ (CT) technology provides a simple-to-use, leak-free connection for both the internal standard and sample, every time.

Teledyne Photon Machines and Glass Expansion present two interface designs that increase the flexibility and signal stability that can be achieved with the Irida system.

***Live: Tuesday February 23, 2021 & Wednesday February 24, 2021*** Spectroscopy magazine and the Society for Applied Spectroscopy (SAS) are pleased to present a joint virtual conference on February 23 and 24, 2021, called “Atomic Spectroscopy in Practice.” This two-day event will provide highly practical information for atomic spectroscopists and analytical laboratory staff working with molecular atomic techniques. *** On demand available after final airing until Feb. 24, 2022***

*** Live: Tuesday, November 3, 2020 at 11am EST| 8am PST| 4pm GMT| 5pm CET***Join us for a great educational opportunity for the ICP-MS analyst. Learn tips on ICP-MS cone selection, conditioning, and maintenance, in addition to best microwave digestion practices to achieve low level analysis with minimal background interferences. ***On demand available after final airing until Nov. 3, 2021***

Sponsored Content
Why, when, and how to maintain ICP-MS interface cones, in addition to the importance of cone conditioning is discussed, along with the benefits of Platinum tipped cones.

The analytical performance of your ICP can often be improved by a careful choice of torch, spray chamber and nebulizer components by taking into account the type of samples that will be analyzed. In this article, we focus on the “hard to measure” ICP-OES elements, As, Se and Pb to determine whether we can improve detection limit performance by selection of appropriate sample introduction components.
Glass Expansion designed and patented the D-Torch, a revolutionary, demountable torch. The D-Torch uses high-precision engineering to provide the benefits of a demountable torch, such as lower running costs, chemical inertness, and configurable injector geometry, without compromising usability, performance, or durability. In this report, we discuss the effects of harsh matrices on torches, as well as the features, benefits, and improvements in analysis achieved with the D-Torch.

Sponsored Content
The Niagara Rapid Rinse is the simplest, lowest-cost method of improving throughput for ICP-MS applications. Time saved is typically 30%.

Sponsored Content
The Niagara Rapid Rinse is the simplest, lowest-cost method of improving throughput for ICP-MS applications. Time saved with the Niagara is typically 30%, with little to no changes to the current method settings and no degradation in performance.

Sponsored Content
Addressing the challenge of heavy metals testing in cannabis How to identify nebulizer issues Improved washout with a cyclonic spray chamber


Application Notebook

Sponsored Content
An accessory to an ICP optical or mass spectrometer is described which speeds sample analysis and reduces carryover. This streamlined switching valve accessory is easy to install and uninstall, requires minimal training, and has a dramatically lower price point


February 1st 2020

September 1st 2016

November 30th 2016

September 3rd 2017