This work demonstrates the ability of the PinAAcle 500 AA spectrometer to accurately measure copper, iron, and manganese in wine samples at levels which meet the regulations imposed by China for imported wine.


Spectroscopy
This work demonstrates the ability of the PinAAcle 500 AA spectrometer to accurately measure copper, iron, and manganese in wine samples at levels which meet the regulations imposed by China for imported wine.

Spectroscopy
This paper describes the challenges faced by labs analyzing mercury in fish samples when using conventional technologies such as CVAA and ICP and how direct mercury analysis can overcome these challenges.

Spectroscopy
Due to its ability to absorb trace amounts of mercury, analysis of lichen is a potential model for mercury contamination in a micro-ecosystem modeling system. The purpose of this application note is to validate the capabilities of the QuickTrace® M-7600 Cold Vapor Atomic Absorbance (CVAA) mercury analyzer in the ug/L range.

Spectroscopy
The analysis of glass and raw materials is demonstrated in the manufacturing of soda-lime glass, which makes up 90% of the global glass production and is used to make windows, glassware and bottles. The Rigaku NEX CG spectrometer yields excellent performance for the elemental analysis of raw materials and final characterization of finished glass.

Spectroscopy
Typically, there are many target elements included in the testing of drinking water, such as sodium (Na), calcium (Ca), lead (Pb) and cadmium (Cd). This note presents how ICPE spectrometry can provide accurate measurement of many elements, from those present at trace levels to those at high concentrations.

Application Notebook
Ancient Roman builders designed maritime concrete harbor structures to remain intact in the aggressive seawater environment for very long periods of time.

Application Notebook
Moxtek's ULTRA-LITE X-ray source is a very small self contained X-ray source (X-ray tube and high voltage power supply) for use in portable X-ray applications, such as the handheld X-ray fluorescence (XRF) spectrometers.

Application Notebook
This report introduces an X-ray fluorescence (XRF) analysis for the detection of ppb levels of hazardous heavy elements in wastewater and river water using "Ultracarry®" high sensitivity micro-droplet filter paper and the "Ultradry™" vacuum dryer.

Application Notebook
Single reaction chamber microwave digestion offers significant benefits over traditional microwave digestion for pharmaceutical samples: higher sample throughput, reduced labor and consumables costs, simplified workflow, and superior digestion quality.

Spectroscopy
Lasers have many different scientific uses. Some analytical scientists are advancing the use of laser-based techniques to analyze works of art and other ancient artifacts. Laser-ablation surface-enhanced Raman microspectroscopy (LA-SERS) can analyze art and artifacts to accurately identify the various components inside them. Spectroscopy recently spoke with Pablo Londero, an Associate Conservation Scientist at the Institute for the Preservation of Cultural Heritage (IPCH) at Yale University, and Marco Leona, the head of scientific research at the Metropolitan Museum of Art, about their work in this area.






Spectroscopy
Determination of trace metals in oil and petroleum typically is based on ICP-OES methods, requiring signficant sample preparation and expensive instrumentation. This article presents an alternative method, based on the use of a handheld energy-dispersive X-ray fluorescence analyzer, that involves minimal sample preparation, uses authentic standards for calibration, gives low parts-per-million detection limits, and provides significant time and cost savings.

Spectroscopy
The California Department of Public Health has proposed to establish the first regulatory limit in the United States for hexavalent chromium (chromium-6) in drinking water. The proposed Maximum Contaminant Level (MCL) sets the limit for hexavalent chromium at 10 parts per billion. California, like those of other states and United States federal government, currently only regulates total chromium levels.

Application Notebook
The new Savillex C400d PFA concentric nebulizer for ICP-MS combines the reliability of a low flow glass nebulizer with the chemical resistance and low elemental background of a PFA concentric nebulizer.

Application Notebook
Sample matrices with high organic content have created a significant challenge for sample preparation methods.

Application Notebook
This application note introduces an Application Package for quantitative analysis of additive elements in polymer.

Application Notebook
This application note describes the capability of the Teledyne Leeman Lab's Prodigy7 High-Dispersion ICP for performing analysis according to SW-846 Method 6010C.

Application Notebook
Moxtek now has a full energy dispersive X-ray fluorescence detector solution with Moxtek's XPIN detectors and our new MXDPP-50 electronics.

Application Notebook
Demonstration of the advantages of using the Orbis micro-XRF elemental analyzer rather than other analysis techniques to perform elemental analysis through a plastic barrier and/or at atmospheric pressure.

Application Notebook
SciAps has developed a handheld analyzer based on laser induced breakdown spectroscopy (LIBS).

Everyone loves a list, and the editors of Spectroscopy are no exception! In 2013, Spectroscopy covered a wide array of topics throughout the year to bring you the most relevant information for your work, on topics ranging from selecting the right ICP-MS system to deciding which Raman technique is right for you, from our annual salary survey to calibration transfer. Here is a list of 13 popular articles and columns from 2013