This application note describes quantitative digestion of biofuel samples and their precursors without soot formation in the shortest measurement time.

This application note describes quantitative digestion of biofuel samples and their precursors without soot formation in the shortest measurement time.

This application note details the RA802’s ability to deformulate the make-up of a transdermal nicotine patch.

Using Analytik Jena’s patented iCRC technology for interference removal, we measured 82 drinking water samples per h with 21 elements (+4 internal standards).

This app note describes the Hg analysis of fish and animal tissue without any sample preparation and using a single, matrix-independent calibration.

In this application Edinburgh Instruments RMS1000 Raman Microscope, with a heated stage, is used to observe phase transitions in 2 polymers - polyethylene and nylon-6.

Sample preparation and analysis of metals in disposable, non-medical face masks with the Avio® 550 Max ICP-OES to meet the criteria defined in ISO 18562- 4:2017.

Raman OEM applications need consistent spectra to deliver dependable answers. Learn how to achieve >99.5% unit-to-unit agreement using a series of simple corrections.

Analytik Jena’s High-resolution ICP-OES with high sensitivity complies with concentration limits of drinking water regulations without further accessories required.

New ICP-OES plasma viewing technique doubles the sensitivity in the analysis of environmental samples from water, wastewater, soils, and sludges on the SPECTROGREEN.

This application note describes how the Vitesse TOF-ICP-MS from Nu Instruments collects raw data and generates megapixel images for geological and biological samples.

This application note reviews a new series of high-performance PFA nebulizers that were designed for low sample volume ICP-MS applications and feature a demountable uptake line.

This application note discusses specular reflectance as a technique to analyze polymer samples using a Nicolet Summit FTIR spectrometer

This application note demonstrates the analysis of distinct polymorphs with the Rigaku Progeny 1064 nm handheld Raman analyzer.

Application of HR-CS Flame AAS for determination of macro-micro and ultra-micro element contents using only one dilution factor in a single measurement run.

In this application note, Edinburgh Instruments highlights how Raman spectroscopy, in combination with chemometrics, can be used to identify cooking oil adulteration.

This application note details the RA802’s ability to deformulate the make-up of a transdermal nicotine patch.

World’s smartest palm spectrometer for 400–2500 nm has one-button operation, miniaturized optics, and high efficiency for maximum sensitivity with ultrafast acquisition.

This case study demonstrates how the Tactic-ID GP handheld Raman analyzer was used to detect contamination in a commercial hand sanitizer.


New ICP-OES plasma viewing technique doubles the sensitivity in the analysis of environmental samples from water, wastewater, soils, and sludges on the SPECTROGREEN.

Learn here how to identify polymorphic transformation by using Raman and the Crystalline instrument.

To avoid risky and costly exploration, petroleum companies use isotope fingerprinting for the identification of sources of oil and natural gas.

This app note demonstrates the effectiveness of utilizing the NanoRam-1064 for analyzing and identifying botanical ingredients while minimizing fluorescence.

Learn about a novel narrow-linewidth 785 nm laser and how it can be used in low-frequency Raman spectroscopy, especially for inspection of pharmaceutical products.

This application note reviews a new series of high-performance PFA nebulizers that were designed for low sample volume ICP-MS applications and feature a demountable uptake line.

This application note explains the concept of Raman Concatenation, which allows users to visualize the Raman spectra from 0 to 4000 cm by utilizing two lasers.

Raman spectroscopy is an advantageous analysis technique to the pharmaceutical research industry for its easy operation and screening accuracy.

We describe several Ocean Insight NIR spectrometer options that meet a significant range of price, performance, and application criteria.

This application note details how the Renishaw Virsa Raman analyzer can be used to study catalysts, with vanadium oxide as an example.

In vaccine production, level of antigens in products must be controlled. Antigens typically consist of proteins. The quantification of total protein is a method of choice.